Montana Bids > Bid Detail

ISBEE Sources Sought PM Services for Sterilizer and Washer Equipment IHS FPSU

Agency:
Level of Government: Federal
Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
Opps ID: NBD00159899853804831
Posted Date: Oct 6, 2023
Due Date: Oct 10, 2023
Source: https://sam.gov/opp/c67959f61b...
Follow
ISBEE Sources Sought PM Services for Sterilizer and Washer Equipment IHS FPSU
Active
Contract Opportunity
Notice ID
75H709-FP24S-001
Related Notice
Department/Ind. Agency
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier
INDIAN HEALTH SERVICE
Office
BILLINGS AREA INDIAN HEALTH SVC
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information View Changes
  • Contract Opportunity Type: Sources Sought (Updated)
  • All Dates/Times are: (UTC-06:00) MOUNTAIN STANDARD TIME, DENVER, USA
  • Updated Published Date: Oct 06, 2023 07:39 am MDT
  • Original Published Date: Oct 03, 2023 07:30 pm MDT
  • Updated Response Date: Oct 10, 2023 12:30 pm MDT
  • Original Response Date: Oct 06, 2023 02:30 pm MDT
  • Inactive Policy: 15 days after response date
  • Updated Inactive Date: Oct 25, 2023
  • Original Inactive Date: Oct 21, 2023
  • Initiative:
    • None
Classification
  • Original Set Aside: Buy Indian Set-Aside (specific to Department of Health and Human Services, Indian Health Services)
  • Product Service Code: J065 - MAINT/REPAIR/REBUILD OF EQUIPMENT- MEDICAL, DENTAL, AND VETERINARY EQUIPMENT AND SUPPLIES
  • NAICS Code:
    • 811210 - Electronic and Precision Equipment Repair and Maintenance
  • Place of Performance:
    Poplar , MT 59255
    USA
Description View Changes

Amendment 001:



The amendment to this sources sought notice is two-fold:



1) Provide the make and serial numbers of the equipment, which was inadvertently omitted from the Government-Furnished Equipment and Information Section of the original notice.



No. Equipment Serial Number



1 PROF 433/533 Sterilizer BAA077666



2 PROF 433/533 Sterilizer BAA099641



3 PROF 433/533 Sterilizer BAA097335



4 PROF IntegratedBoilers 30kW-45kW GET1230280-P21



5 PROF IntegratedBoilers 30kW-45kW GET1216283-P20



6 PROF IntegratedBoilers 30kW-45kW GET1161662-Z16



7 PROF RO System SRB 400-MRG 1200 GTR210008



8 PROF RO System SRB 400-MRG 1200 GTR210009



9 PROF RO System SRB 400-MRG 1200 G140286



10 PROF 86 Series Washer WAA097790



11 PROF 86 Series Washer WAA097802



2) Attach the IEE Representation form, which was inadvertently omitted from the original notice. Responses to this notice are to fill out and sign the form, and include it with the emailed submission.



The response due date is extended to 10/10/2023.



_________________________



This is a PRE-SOLICITATION SOURCES SOUGHT NOTICE only. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS OR PRICING AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall not be construed as a solicitation or as an obligation on the part of the Indian Health Service. Responses to this notice will be treated only as information for the Government to consider as part of their market research efforts. The information provided will be used by the Government in developing its acquisition strategy regarding possible set aside for Indian-Owned Small Business Economic Enterprise (ISBEE) and other socio-economic categories of small business. Interested parties are responsible for adequately marking proprietary, restricted or competition sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this notice and parties responding will not be entitled to payment for direct or indirect costs incurred in responding to this notice. The North American Industry Classification System (NAICS) code for this requirement is 811210, Electronic and Precision Equipment Repair and Maintenance, with an SBA Small Business Size Standard of $34.0 million. 1. Please identify any of your firm’s existing contract vehicles (e.g., GSA federal supply schedules) which provide similar services as those described in the Statement of Work (attached). 2. Please provide all social-economic categories of your firm (e.g., ISBEE, SDVOSB, VOSB, WOSB, IEE, Large Business, 8a, etc.) as well as your firm’s SAM Unique Entity ID number (replaces DUNS number) and Government Contract POC. All questions and responses must be submitted via email to Prudence.Yellowowl@ihs.gov, no phone calls will be accepted. Please note 75H709-FP24S-001 in the subject line of your response. See attached draft Statement of Work for details of the requirement. STATEMENT OF WORK PROJECT TITLE: Sterilizer and Washer Preventative Maintenance Service for Fort Peck Service Unit (FPSU) BACKGROUND/PURPOSE: Preventative Maintenance services on a quarterly basis are required on sterilizing equipment and components per The Joint Commission requirements. SCOPE: Quarterly Preventative maintenance is required for the service unit’s medical sterilizers, boilers, RO Systems and semi-annual maintenance on the washer disinfector systems equipment located at the Fort Peck Service Unit’s medical clinics, Verne E Gibbs Health Center, White Buffalo Clinic located in Poplar, MT, and Chief Redstone Health Center located in Wolf Point, MT. The preventative maintenance will be completed per manufacturer’s recommendation for annual maintenance. APPLICABLE DOCUMENTS: Joint Commission Accreditation, Manufacturer Specifications for Equipment SPECIFIC TASKS: Provide preventative maintenance services. Schedule must be coordinated through the FPSU POC. Task 1: Qualified technician shall conduct complete preventative maintenance per manufacturer’s recommendation for the FPSU sterilizer and washer equipment. The Contractor shall provide all transportation, personnel, materials, labor, and equipment required to perform the preventative maintenance service. Task 2: Provide Written Report that Documents Location, Barcode, Serial Number, Manufacturer, Nomenclature, Model number, PM checklist with results, any equipment issues/comments or required parts. Documentation listing: for each piece of equipment will have documentation which reflects Location, Barcode, Serial Number, Manufacturer, Nomenclature, Model number, PM checklist with results, any equipment issues/comments or required parts. DELIVERABLES AND DELIVERY SCHEDULE: Biomedical preventative maintenance shall be provided within 30 calendar days of award. A written report of the results shall be provided by email to the Fort Peck Service Unit Facility Manager within 15 calendar days of completion. GOVERNMENT-FURNISHED EQUIPMENT AND INFORMATION: FPSU will present all sterilizers and washers to the Contractor for preventative maintenance services. PLACE OF PERFORMANCE: Getinge 433-HC-E sterilizer, boiler, RO System and washer disinfector components are located at the Fort Peck Service Unit’s medical clinic, Verne E Gibbs Health Center, White Buffalo Clinic located in Poplar, MT and Chief Redstone Health Center located in Wolf Point, MT. PERIOD OF PERFORMANCE: Anticipated start date is 30 days after contract award for 12 months. SECURITY: Contractor technicians are required to check in with FPSU POC upon arrival at facility to obtain access and location information.


Attachments/Links
Attachments
Document File Size Access Updated Date
IEE Representation Form.pdf (opens in new window)
130 KB
Public
Oct 06, 2023
file uploads

Contact Information View Changes
Contracting Office Address
  • 2900 FOURTH AVE. NORTH - PO BOX 366
  • BILLINGS , MT 59107
  • USA
Primary Point of Contact
Secondary Point of Contact


History

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >