1 YEAR SERVICE AGREEMENT FOR MACSQUANT ANALYZER

Agency: HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Level of Government: Federal
Category:
  • J - Maintenance, Repair, and Rebuilding of Equipment
Opps ID: NBD00159743758849211
Posted Date: May 16, 2023
Due Date: May 22, 2023
Solicitation No: NOI-NIAID-23-2174355
Source: https://sam.gov/opp/91aa777be2...
Follow
1 YEAR SERVICE AGREEMENT FOR MACSQUANT ANALYZER
Active
Contract Opportunity
Notice ID
NOI-NIAID-23-2174355
Related Notice
Department/Ind. Agency
HEALTH AND HUMAN SERVICES, DEPARTMENT OF
Sub-tier
NATIONAL INSTITUTES OF HEALTH
Office
NATIONAL INSTITUTES OF HEALTH NIAID
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information
  • Contract Opportunity Type: Presolicitation (Original)
  • All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
  • Original Published Date: May 16, 2023 03:56 pm EDT
  • Original Response Date: May 22, 2023 04:00 pm EDT
  • Inactive Policy: 15 days after response date
  • Original Inactive Date:
  • Initiative:
    • None
Classification
  • Original Set Aside:
  • Product Service Code: J066 - MAINT/REPAIR/REBUILD OF EQUIPMENT- INSTRUMENTS AND LABORATORY EQUIPMENT
  • NAICS Code:
    • 811310 - Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance
  • Place of Performance:
    Hamilton , MT 59840
    USA
Description

This is a Notice of Intent, not a request for proposal. The National Institute of Allergy and Infectious Diseases (NIAID) of the National Institutes of Health (NIH) intends to negotiate on an other than full and open competition basis with Miltenyi Biotec Inc. to procure:



POP 06/01/2023 to 05/31/2024



Qty 1 of cat#160-002-053 MACSQuant Essential Service for MACSQuant Tyto Essential



Minimum Service Requirements:

SERVICES WILL BE PERFORMED WITHIN A “HOT LAB” BSL3 HIGH CONTAINMENT LABORATORY.



Located at: Rocky Mountain Laboratories 903 S 4th St, Hamilton, MT 59840



Technicians must complete all necessary BSL3 trainings (+ refresher courses) with RML Biosafety so that they can go into our BSL3 and work on this piece of equipment.



This instrument currently has a lapse in service coverage.



- Preventive Maintenance Service to include:

- One (1) scheduled maintenance visits

- Performance assurance checks

- Functionality and safety checks

- Safety inspections in accordance with all applicable regulations

- Cleaning of operational contaminations

- Cleaning and greasing of mechanical parts

- Examination of all connecting tubes

- Calibration of instrument components

- Optical alignment

- Performance testing with beads

- Testing of components according to Miltenyi SOP BGL-IS-SOP-000026

- Routine inspection and replacement of wearing parts



Repair Service

- Repair of instrument defects

- On-site response time within 2 working days

- Allocation of parts and labor for all necessary repairs

- Technical Support Service 24/5

- Software Update Service



Technical Support Service 24/5

- Interactive telephone and electronic mail support for the purpose of resolving

technical support incidents

- Email and chat support available 5 days a week

- Phone support availability 24 hours a day, 5 days a week



Software Update Service

- Standard device software updates (Operating system and standard applications) are performed during preventive maintenance to keep the instrument up to date with the newest software releases



The statutory authority for this sole source requirement is 41 U.S.C. 1901 (a) (1) as implemented by FAR 13.106-1 only one responsible source and no other supply of service will satisfy agency requirements. THIS IS NOT A REQUEST FOR PROPOSAL. All responsible sources that could provide comparable services may submit a capability statement that will be considered by email (subject line to reference NOI-NIAID-23-2174355 to Diana Rohlman at diana.rohlman@nih.gov by 4:00 pm eastern standard time May 22, 2023. Capability statements must address all minimum service requirements within posting to be considered. Any third-party responses must guarantee service equal to that of a direct contract with Miltenyi Biotec, the instrument manufacturer, including priority response times. All responses received by the closing date of this synopsis will be considered by the Government. A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government.


Attachments/Links
Contact Information
Contracting Office Address
  • 5601 FISHERS LANE, SUITE 3D11
  • BETHESDA , MD 20892
  • USA
Primary Point of Contact
Secondary Point of Contact
History
  • May 16, 2023 03:56 pm EDTPresolicitation (Original)

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >