Custom Biosafety Cabinet for RML Campus
Agency: | HEALTH AND HUMAN SERVICES, DEPARTMENT OF |
---|---|
Level of Government: | Federal |
Category: |
|
Opps ID: | NBD00159470534630659 |
Posted Date: | Jun 15, 2023 |
Due Date: | Jun 22, 2023 |
Solicitation No: | NOI-NIAID-23-2176759 |
Source: | https://sam.gov/opp/ebb14e5579... |
Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.
- Contract Opportunity Type: Presolicitation (Original)
- All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
- Original Published Date: Jun 15, 2023 01:52 pm EDT
- Original Response Date: Jun 22, 2023 05:00 pm EDT
- Inactive Policy: 15 days after response date
- Original Inactive Date: Jul 07, 2023
-
Initiative:
- None
- Original Set Aside:
- Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
-
NAICS Code:
- 334516 - Analytical Laboratory Instrument Manufacturing
-
Place of Performance:
Hamilton , MT 59840USA
PRE-SOLICITATION NOTICE ** NOTICE OF INTENT
NOI-NIAID-2176759
NAICS – 334516, Analytical Laboratory Instrument Mfg
This is a Notice of Intent, not a request for proposal. The National Institute of Allergy and Infectious Diseases (NIAID) of the National Institutes of Health (NIH) intends to negotiate on an other than full and open competition basis with NuAire, Inc to procure a custom Biosafety Cabinet to convert a BSL3 animal facility into a study unit for immunology and molecular biology of infectious viruses on the Rocky Mountain Laboratories campus.
Building 25 houses RML’s BSL3 animal facility consisting of several suites separated based on pathogen and/or vector. Primary containment, namely biosafety cabinets, are critical for protection of personnel from infectious pathogens. Suite B will be changing ownership to the Laboratory of Neurological Infections and Immunity (LNII) requiring a transition from animal research suite to focus on the study of the immunology and molecular biology of infectious viruses. This involves the introduction of new specialized equipment into the BSL3 animal facility. One piece of equipment, a Cytoflex flow cytometer, needs to be contained in a Class II A2 biosafety cabinet to safely run samples. The Cytoflex cytometer has dimensions of 30”W x 30”D x 36”H. The largest standard BSC from any manufacturer is 6’ width with internal work dimensions of 69 7/8”W x 20 7/8”D x 28 ½”H. To accommodate the Cytoflex equipment for this type of research, the purchase of a custom biosafety cabinet is required because all standard size cabinets are not large enough to fit the Cytoflex cytometer with adequate room for proper air flow, sample and personnel protection.
The statutory authority for this sole source requirement is 41 U.S.C. 1901 (a) (1) as implemented by FAR 13.106-1 only one responsible source and no other supply of service will satisfy agency requirements. THIS IS NOT A REQUEST FOR PROPOSAL. All responsible sources that could provide comparable services may submit a capability statement that will be considered by email (subject line to reference NOI-NIAID-23-2176759) to Dana Monroe at dana.monroe@nih.gov, by 5:00pm eastern daylight savings time Thursday, June 22, 2023. All responses received by the closing date of this synopsis will be considered by the Government. A determination not to compete this requirement, based upon responses to this notice, is solely within the discretion of the Government.
- 5601 FISHERS LANE, SUITE 3D11
- BETHESDA , MD 20892
- USA
- Dana Monroe
- dana.monroe@nih.gov
- Phone Number 4063759814
- Jun 15, 2023 01:52 pm EDTPresolicitation (Original)
TRY FOR FREE
Not a USAOPPS Member Yet?
Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.